  HB Serial line speed change
 
Hi! I'm asking this again, since I've got no definitive answer: Is it possible to change the speed of the HB serial line to 19200? I need to communicate with a device which has a fix 19200 setting! Is it possible or can I forget the HB for this (...) (25 years ago, 23-Jul-99, to lugnet.robotics.handyboard)
 
  Re: HB Serial line speed change
 
(...) The definitive answer comes from the "pink" book, which everyone should have (especially now that you can get it on CD-rom for free by filling out the form on the Mot web site!) Which basically says "No you can't do that." But it says it in a (...) (25 years ago, 24-Jul-99, to lugnet.robotics.handyboard)
 
  Re: HB Serial line speed change
 
(...) I haven't looked at the schematics for the handyboard for a while, but if you use an E-series processor, then I think you can go up to 12MHz (3 MHz E-Clock). I'm not sure whether the rest of the Handyboard could take the increased speed, and (...) (25 years ago, 26-Jul-99, to lugnet.robotics.handyboard)