Hello all,
I have a Polaroid 6500 connected to the HB in the standard and well
documented fashion. It is working and delivers values that approximate the
correct distances. However, it is somewhat inconsistent. For example it
will return a lower (shorter) value when first used. This will gradually
increase and become more accurate. I am using a multi-tic and an average
for the readings in hopes of getting an overall average reading. Has anyone
experienced inconsistent readings from thier sonar? Have they been able to
correct it?
Please help!
Bob Kelly
|
|
Message has 1 Reply: | | Re: POLAROID 6500 INCONSISTENT
|
| Bob, I do experience the same thing and taking the average does not work correctly. I compare the "distance" between the values (I have it get three) and throw out the one that is farthest away. Then I take the average of the remaining two. After (...) (25 years ago, 28-Jun-99, to lugnet.robotics.handyboard)
|