I also found that my neon light in my magnifying lens lamp caused erroneous
readings.  When I turned it off or moved it away the readings normalized
(gave the correct results).  Shielding wasn't effective in this instance.

I did completely away with the ribbon cable supplied with the sonar kit.  I
installed 9-pin D connectors at each end and ran shielded 4 pair cable
between the HB and the sonar board.

I provided a separate power supply for the sonar system (4 - 1.2 volt
cadmium) and located it close to the actual sonar.  Thus eliminating the
high current pulse and resultant magnetic field through the 4 pair cable.

Hope this helps.

Ted Mylenbusch
amylen@worldnet.att.net


> -----Original Message-----
> From: Guy & Gad Berg [mailto:gberg@netvision.net.il]
> Sent: Monday, March 01, 1999 4:16 AM
> To: handyboard@media.mit.edu
> Subject: Polaroid sonar problems
> 
> 
> hi!
> 
> Our group is still struggling with the polaroid sonar. We can't get any
> coherent reading, only readings that are in the range 470-515, which
> aren't effected by the measured distance.
> We have the capacitor and resistor installed as required.
> We tried using a 150ms delay (instead of 50) and we average our
> readings, we tried taking every tenth reading and displaying it, but
> nothing seems to work.
> We know there are people out there who have succeeded! PLEASE, tell us
> what you did.
> Thanks.
>     Guy.
> 
> 



Message is in Reply To:
  Polaroid sonar problems
 
hi! Our group is still struggling with the polaroid sonar. We can't get any coherent reading, only readings that are in the range 470-515, which aren't effected by the measured distance. We have the capacitor and resistor installed as required. We (...) (28 years ago, 1-Mar-99, to lugnet.robotics.handyboard)

3 Messages in This Thread:


Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR