To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.handyboardOpen lugnet.robotics.handyboard in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / Handy Board / 5310
5309  |  5311
Subject: 
ROVER
Newsgroups: 
lugnet.robotics.handyboard
Date: 
Tue, 2 Feb 1999 19:46:19 GMT
Original-From: 
SHETTI.NITIN.MANGESH <shettin@giasbmc.vsnl.net.IHATESPAMin>
Viewed: 
764 times
  
Dear Mr Fred Martin,
I hope you remember that we in India were making a rover ,which in
the end ran into some problems.We had to present the inoperational rover
only for the exhibition. Now,after the exhibition we are trying to make
the rover work.
We have noticed two things-7404 is not being accepted by the handy
board,this is inspite of the fact that 7404 tests fine with the digital IC
tester.
The 74138 pins must be pulsing according to the handy board
assembly manual, but when we checked it wasn't.
Can anybody make sense of what is going on? Please reply soon.
Yours sincerely,
    Nitin



Message has 1 Reply:
  Re: ROVER
 
are you using 74HC04, and not plain 7404? you must use all HC type chips in the Handy Board. fred In your message you said: (...) (26 years ago, 2-Feb-99, to lugnet.robotics.handyboard)