Does anyone know the impedance onto the sensor inputs on the HB and/or any
suggestions for setting them to receive signals sent at 220K Ohm.
Joe Martin
joema@mpx.com.au



Message has 1 Reply:
  Re: input impedance
 
(...) Hmmmmmm.. as I recall, there are 47k pullups on those inputs. These are used to condition the signals when used as a digital input. The 'HC11 pink book suggests that any input resistance of greater then 10K will "...degrade A/D accuracy." The (...) (26 years ago, 11-Jun-98, to lugnet.robotics.handyboard)