 | | Re: JRM code and Reset
|
| Dan, Yes, I did cut the trace for external motor power. I know the HB and the motor power "+" sources are isolated because I not only checked with a VOM, but I removed the motor supply batteries and when I run my motor test program (remember, no (...) (25 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
| | |  | | Re: JRM code and Reset
|
| Since it seems like everything else has been checked, I have one other suggestion after looking at my pcode source. If the "start" button on the HB is pressed during power on, the autostart will be disabled. Has your hardware been hacked at all, (...) (25 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
| | |  | | Re: JRM code and Reset
|
| Wow, What a bugger! This is one of the strangest cases I've seen. Works fine while connected, but not when reset. Works fine on my board either way. Memory and 68HC11 have been traded out. Scope shows no voltage drop at Mem-power durring reset. Both (...) (25 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
| | |  | | Re: IR Routines
|
| (...) Hi Dave, I uploaded a modified version of those IR routines to handyboard.com as well as the Rug Warrior group ((URL) the RW group, I also have a version of pcode v3.1 with bug fixes and new capabilities. Could you convey this information to (...) (25 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
| | |  | | Re: JRM code and Reset
|
| Fred, Thanks for the info on how IC determines whether to auto-start a program or not. Based on your suggestions ---- I just finished downloading the open-source (free) version of IC. I had been running Newton Labs 3.1 and most recently 3.2. I (...) (25 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
| |