To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 3219
    Re: Communicating with Cybermaster not easy —Kay Neuenhofen
   Sten, your problem is probably the following: you need to send the complement of the checksum as well, so the complete packet would look like this: 0x55 0xFF 0x00 0x10 0xEF 0x10 0xEF (...) -- Did you check the web site first?: (URL) (25 years ago, 25-Jan-99, to lugnet.robotics)
   
        Re: Communicating with Cybermaster not easy —Peter Ljungstrand
   Again: The low-level packet headers are _not_ the same for the RCX and the CyberMaster. (See (URL) for the RCX details) This is the CyberMaster settings: The serial port should have the same settings as was for the RCX, as originally described by (...) (25 years ago, 26-Jan-99, to lugnet.robotics)
 

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR