Subject:
|
Re: legOS not working with external relay switches
|
Newsgroups:
|
lugnet.robotics
|
Date:
|
Mon, 11 Mar 2002 20:53:47 GMT
|
Viewed:
|
838 times
|
| |
| |
three 2200uf capacitors fixed the problem
but does anyone know why the difference between legOS and the standard
firmware??
"Kingsley Gifford" <kgifford@thezone.net> wrote in message
news:Gss5st.I5F@lugnet.com...
> I'm in the process of "reviving" past inventions with my new knowledge
> of legOS.
>
> One such invention (if you can call it that) used 3 12V relay switches
> to control external circuits. Full power on the outputs would trigger
> the relays.
>
> however, under legOS the relays will not fire. I use
> motor_a_dir(fwd);
> motor_a_speed(MAX_SPEED);
>
> but the relay only buzzes/humms as it did when used with nqc at anything
> less than full power.
>
> What's the command for full power to the outputs under legOS?
>
> --i didn't try a program today with nqc, but i did reset the rcx and
> used program 1 in the rom. it fires the relay fine, so it is not a
> hardware problem.
>
> thanks
>
>
>
|
|
Message is in Reply To:
| | legOS not working with external relay switches
|
| I'm in the process of "reviving" past inventions with my new knowledge of legOS. One such invention (if you can call it that) used 3 12V relay switches to control external circuits. Full power on the outputs would trigger the relays. however, under (...) (23 years ago, 10-Mar-02, to lugnet.robotics)
|