Has anyone
done any work on trying to hook up 4+ LIGHT SENSORS to the RCX?
Thanks
Ahui

LEGO Light sensors are a powered type and fairly tricky to multiplex.  You
would need to recreate the whole powered interface for each added sensor.
Also there is only a limited amount of power available at a RCX sensor
input.  You could use a multiplexer like the one on my page
http://www.plazaearth.com/usr/gasperi/mux.htm if you use passive CdS light
sensors like the ones on this page
http://www.plazaearth.com/usr/gasperi/cds.htm.  I think you would need to
add a 10K pullup for each light sensor.