To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 10811
10810  |  10812
Subject: 
Re: Control six Micro Scouts with a fiber optic module?
Newsgroups: 
lugnet.robotics, lugnet.robotics.microscout, lugnet.robotics.codepilot
Date: 
Thu, 24 Feb 2000 20:25:01 GMT
Viewed: 
7762 times
  
It's eight fiber cables on my fiber optic modules.

Dennis

Doug Weathers wrote:

I had this really sick idea last night, and I thought I'd throw it out for
discussion.

In theory, you could control up to six Micro Scouts or Code Pilots using two
motor outputs and one sensor input.

Each of the six fiber optic cables from the fiber optic module go to a
single Micro Scout's light sensor.

One motor output runs a motor that turns the fiber optic module.  A rotation
sensor tells the RCX where the shaft is, so the correct Micro Scout can be
selected.

The other motor output is connected to the fiber optic module.  The RCX now
pulses this output to send VLL commands to the selected Micro Scout.

Note that as specified here this is a "pure Lego" solution!  The guys with
glue and X-acto knives can also get into the act if they want (ewww....)

If we had a way to split and join fiber optic cables, we can control
multiple Micro Scouts with one of the six channels available from the fiber
optic module.  For instance, you could control five Micro Scouts
individually, and the sixth channel runs to every Micro Scout so you can
tell them all to do something simultaneously (like to turn off all the
motors).

You could use TFM's light/motor block
<http://www.akasa.bc.ca/tfm/lego_l_m.html> to run the motor and flash the
LED in the fiber optic module with a single motor output.

Come to think of it, a directional transmission or a simple ratchet would do
the same thing.  Run the motor forwards, it turns the FOM (which is also
connected so it's lit up while the motor runs).  Run it backwards, the
ratchet engages and keeps the FOM from turning and you can pulse the power
to send VLL code.  The drawback is that when it's turning forwards the light
is on, but the Micro Scout will probably ignore the flash as the LED goes
by.

Something to think about, anyway.

--
Doug Weathers, http://www.rdrop.com/~dougw
Portland, Oregon, USA
Don't spam me - I know how to use http://www.spamcop.net
"On a clear disk you can seek forever"

--
Dennis Williamson - Certified Y2K Complacent

Bad News: The next millenium starts on a Monday.
Good News: You get the day off.

(remove .NO and SPAM. to reply)



Message has 1 Reply:
  Re: Control six Micro Scouts with a fiber optic module?
 
Congrats, Dennis You just wrote message 110,000!!! - John Rudy (having nothing to do with this conversation) (25 years ago, 25-Feb-00, to lugnet.robotics, lugnet.robotics.microscout, lugnet.robotics.codepilot)

Message is in Reply To:
  Control six Micro Scouts with a fiber optic module?
 
I had this really sick idea last night, and I thought I'd throw it out for discussion. In theory, you could control up to six Micro Scouts or Code Pilots using two motor outputs and one sensor input. Each of the six fiber optic cables from the fiber (...) (25 years ago, 24-Feb-00, to lugnet.robotics, lugnet.robotics.microscout, lugnet.robotics.codepilot)

5 Messages in This Thread:


Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact

This Message and its Replies on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    
Active threads in Robotics

 
Verified and Trusted Team of Hackers
4 minutes ago
Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR