 | | RE: SetWatch() only accepts constants
|
|
Instead of sending ByteCodes from the PC and getting the RCX to interpret them, you can construct and send the SetWatch() OpCode plus the correct "constant" time and send it through Spirit.OCX (or directly, depending of the platform). (...) (25 years ago, 7-Aug-01, to lugnet.robotics.rcx.nqc)
|
| |
 | | SetWatch() only accepts constants
|
|
I just wrote a task and function that cause the RCX to receive data from the PC and then set the time on the RCX using SetWatch(). Unfortunately, I didn't realize that SetWatch() only accepts constants. NQC complained when integer variables were (...) (25 years ago, 7-Aug-01, to lugnet.robotics.rcx.nqc)
|
| |
 | | Re: How can I build sensor to measure eeg
|
|
(...) First, normal EEG is between 0.1 and 20 uV, with some exceptions uptil 100 uV. With a special (low noise, high CMRR) instrumentation opamp this would be no problem. Second, the highest frequency is about 120 Hz, so you need to sample at least (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|
| |
 | | Re: Rechargeable Batteries
|
|
I have been interested in what people have to say about using 1.2v cells instead of 1.5v. I don't think the RCX minds, but what is a problem to my mind is that after the RCX motor drivers drop about a volt from the already low 7.2v, you end up (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|
| |
 | | Robolab software
|
|
Any one have a copy of the robolab software for Macintosh available. I have the mindstorm kit but cannot run it on my Mac. I know I can spend $60 bucks at Pitsco and buy a copy, but somehow it doesn't seem fair that they have the Mac version and (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|
| |
 | | Re: Rechargeable Batteries
|
|
(...) Roger, I believe the low voltage is more important. A side issue is the battery indicator that you access through NQC (or Robolab) set up in a scale of 0-9 volts. Fully charged alkalines are 9+ and discharged ones are 6 volts. With NiMH full (...) (25 years ago, 6-Aug-01, to lugnet.robotics.rcx)
|
| |
 | | Re: Rechargeable Batteries
|
|
(...) They have a higher voltage of about 3V and are tricky to charge, if you don't do it right they have a tendency to explode. I've never seen standalone cells and charger. Jürgen (25 years ago, 6-Aug-01, to lugnet.robotics.rcx)
|
| |
 | | Re: How can I build sensor to measure eeg
|
|
(...) 5V/200uV=25000 (or maybe half it the 200uV go both ways). Should be no problem to obtain with multiple OpAmps. There was an article in the german computer magazine c't ((URL) that describes such a beast, but it's not on the web and I don't (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|
| |
 | | Re: How can I build sensor to measure eeg
|
|
(...) First of all, you'd simplify things if you made your amplifier center around 2.5 volts rather than 0. Then your amplified signals would become 2.5 +/- 2.5 which the RCX will like. And if you run the amplifier from a stabilized 5 volt supply, (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|
| |
 | | How can I build sensor to measure eeg
|
|
Hi, I just have a quick question. Hope you guys could give me some pointers. I'd like to build a sensor that measures the voltage of the brain wave like those EEG machines seen in the hospital. And would like the RCX to log the data. I have scanned (...) (25 years ago, 6-Aug-01, to lugnet.robotics)
|