  pneumatic switch control
 
(...) I've been thinking about this a lot... What about using a differential to separate motor direction output. Turning one direction could control one switch and turning the other could control the other switch. The switches could be controlled in (...) (28 years ago, 22-Apr-99, to lugnet.robotics)
 
  Re: Electrolytic Capacitor Ratings [was Re: Choosing Parts?]
 
Generally, cost, accuracy, size, and drift. Ceramic caps are expensive ($/pf) reasonably stable across temperature and acceptably accurate. Electrolytic capacitors are cheap ($/pf) only moderately stable across temperature changes, polarized, and (...) (28 years ago, 22-Apr-99, to lugnet.robotics.handyboard)
 
  Re: Electrolytic Capacitor Ratings [was Re: Choosing Parts?]
 
Kind of. Electrolytics are indeed made by plates in a conductive solution, however when the voltage increases, it pulls the plates together (standard columbs law stuff). When you exceed the rated voltage the force on the plates is enough to pull the (...) (28 years ago, 22-Apr-99, to lugnet.robotics.handyboard)
 
  Re: Electrolytic Capacitor Ratings [was Re: Choosing Parts?]
 
(...) Also (generally) usually less than 1uf (...) and generally >= 1uf (28 years ago, 22-Apr-99, to lugnet.robotics.handyboard)
 
  Re: pneumatic switch control
 
(...) Rather than that, how about triggering one switch automatically at the end of travel of the other? For instance, you won't dump your bucket on the front end loader until it is a max height. Have the motor control the lift are with a sensor (...) (28 years ago, 22-Apr-99, to lugnet.robotics)