| | (...) Stalled, the train motor pulls 950 mA, while the stall current of the NXT motor is a whopping 2 Amps. So a single NXT motor output should easily handle a twin-engine train loaded to the point where it stalls the engine(s)... there's the matter (...) (17 years ago, 7-Oct-07, to lugnet.lego, lugnet.robotics.nxt)
|
| | |
| | | | Re: The Future of Trains David Laswell
|
| | | | (...) So it sounds like a single loop should be no problem under most situations, since I'm not sure I've heard of anyone running three motors on a single train (there's the same issue with how much amperage a power regulator can push). (...) It (...) (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt)
|
| | | | |
| | | | | | Re: The Future of Trains Brian Davis
|
| | | | | (...) Philo kindly corrected me, pointing out that the NXT outputs are regulated down to 1 A, so you couldn't run a dual-truck train all the way to stall. You could still get a good bit of the way there, however. Does anyone know what the peak (...) (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt)
|
| | | | | |
| | | | Re: The Future of Trains Philippe Hurbain
|
| | | | (...) Some precisions here: - NXT stall current is 2A but only for a short time: internal thermal protection will trip at a current much lower than that (exact value depends on temperature and overload duration). A practical value is about 1A - NXT (...) (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt)
|
| | | | |
| | | | | | Re: The Future of Trains Brian Davis
|
| | | | (...) Ah, thank you - so running two stalled train motors would exceed the NXT output, but running one train motor up to a stall conditions should be fine. Out of curiosity, along with the output limitations on the NXT (1 A) and RCX (500 mA), does (...) (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt)
|
| | | | |
| | | | | | Re: The Future of Trains Philippe Hurbain
|
| | | | (...) The linear regulator inside is a 1.5A version if I remember well, but I may be wrong. Cross posted to lugnet.trains trying to get train guru opinion... Philo (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt, lugnet.trains)
|
| | | | |
| | | | | | Re: The Future of Trains Bruce S. Chamberlain
|
| | | | | (...) At BayLTC we usually run four train motors on one loop using stock Controller with a 1.2 amp wall wart. Bruce (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt, lugnet.trains)
|
| | | | | |
| | | | | | Re: The Future of Trains Ross Crawford
|
| | | | (...) The Australian LEGO wall wart is marked 10V @ 7VA on the secondary. I don't recall all the stuff I learnt about the relationship between VA and W, but that seems to me to indicate about 0.7A. I believe this generally reduces as load increases, (...) (17 years ago, 8-Oct-07, to lugnet.lego, lugnet.robotics.nxt, lugnet.trains)
|
| | | | |
| | | | | | Re: The Future of Trains Philippe Hurbain
|
| | | | (...) You are right, the main limitation probably comes from wall wart... You are essentially right for the 0.7A current (though it is not hard limit, rather a safety one). Philo (17 years ago, 9-Oct-07, to lugnet.lego, lugnet.robotics.nxt, lugnet.trains)
|
| | | | |