    using the remote control with legOS —Marc Bangerter
   the LNP stuff is neat, but it seem's that the remote control isn't using either "integrity" or "addressing" protocol how do I access directly the incoming IR buffer ?? I didn't see any source code for "lnp_integrity_set_handler" , how does it work ? (...) (25 years ago, 7-Feb-00, to lugnet.robotics.rcx.legos)
   
        Re: using the remote control with legOS —Martin Cornelius
   (...) with an unpatched legOS-2.3, there's no easy way to do that. The incoming buffer is a static array inside function lnp_integrity_byte(), it's not accessible from outside. However, there is a hard way out (i used it during development of lnpd) (...) (25 years ago, 8-Feb-00, to lugnet.robotics.rcx.legos)
   
        Re: using the remote control with legOS —Marc Bangerter
   it would be nice to be able to use both LNP and remote control (advance tactical robots) I wrote last night a small win prog to figure out how the remote is talking and this is it: +++ // LEGO REMOTE CONTROL (#9738 = ~20 USD) FOR RCX MESSAGE (...) (25 years ago, 9-Feb-00, to lugnet.robotics.rcx.legos)
 