    Re: Reducing voltage —Martin Legault
   (...) Hello, you can put AC or DC voltage at the input of the regulator with no problem as long as you don't put more than 9VAC~14VDC. The internal circuit will take both. So a quick fix that put 4.5~5V DC at the input will ouput about 3~3.2VDC at (...) (15 years ago, 23-Nov-09, to lugnet.trains, lugnet.robotics)
   
        Re: Reducing voltage —Mathew Clayson
   (...) You have to be careful here. The controller is designed to take AC or DC, but the input diodes that that convert the AC to DC are only rated for 1 Amp (1000 milliampres). Make sure your transformer/wallwart is not rated for more than this. (...) (15 years ago, 24-Nov-09, to lugnet.trains, lugnet.robotics)
 