To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.trainsOpen lugnet.trains in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Trains / 30338
30337  |  30339
Subject: 
Re: LEGO 7996 Crossover Motorized and Ballasted - Pictures
Newsgroups: 
lugnet.trains, lugnet.technic, lugnet.build, lugnet.announce.moc, lugnet.loc.uk, lugnet.parts.mod
Followup-To: 
lugnet.trains
Date: 
Mon, 7 Jul 2008 18:50:55 GMT
Highlighted: 
(details)
Viewed: 
105418 times
  
In lugnet.trains, Ondrew Hartigan wrote:
> In lugnet.trains, Scott Wardlaw wrote:
> > > The real broblem with the 7996, wether you metalize it or not is the linked
> > > switch controls. My next project is to split the controlls and add solenoids for
> > 
> > I wish that I had read this a few months ago (when I should have).  I just
> > bought a 7996 with the intention to convert it to 9V.
> > 
> > I am very disapointed that you can not have both of the parallel straights
> > switched to go straight at the same time.  The switching only allows for one to
> > be straight and the other must curve.
> > 
> > I'd be happy to know if you have a good method of splitting the controls and
> > adding solenoids!
> > 
> > Does anyone else have experience with splitting the 7996 controls, or adding
> > solenoids to a regular 9v switching point?
> > 
> > Thanks,
> > Scott
> 
> splitting the controls for the doubble crossover can be done in a couple of
> ways. as soon as i get my hands on a set i will write up some instructions for
> everyone.
> 
> as for selenoids there really is no need. automating 9v/rc switches is fairly
> straight forward.  see:
> http://www.brickshelf.com/cgi-bin/gallery.cgi?f=109777&n=47    see photos that
> start with a "z"  also there are literaly probably 100+ solutions to automate
> all you have to do is look.
> ondrew

I have altered the crossover controls to provide for an all-straight state by
tweaking the springs in the switching rails.

I have also motorized the crossover in such a way that it can be set straight,
TL-BR or BL-TR with two switches (both pneumatic!).

My solution needs just 8 plates below track level in order for there to be no
obstructions above ground, so that larger rail vehicles (8+ wide and 8mm scale)
can use the crossover without grounding or hitting the mechanism.

I ballasted the crossover while I was at it, so that it fits with my layout
ballast scheme.

Pictures here: http://www.brickshelf.com/cgi-bin/gallery.cgi?f=147934
Instructions for building it:
http://www.brickshelf.com/gallery/mbellis/Technic/Pneumatics/Pneumo-Switch-Points/crossover_info.txt

Mark
=============================================================================
Mark J E Bellis 8mm scale LEGO trains



Message has 1 Reply:
  Re: LEGO 7996 Crossover Motorized and Ballasted - Pictures
 
(...) Mark: Nice work! This solution looks really trick. Another great use for the pneumatic system. I wish this stuff was still being produced (although I'm interested to see how the rams work on the new excavator set). I also like you ballast (...) (18 years ago, 8-Jul-08, to lugnet.trains)

Message is in Reply To:
  Re: LEGO 7996 and 9V
 
(...) splitting the controls for the doubble crossover can be done in a couple of ways. as soon as i get my hands on a set i will write up some instructions for everyone. as for selenoids there really is no need. automating 9v/rc switches is fairly (...) (19 years ago, 9-Mar-08, to lugnet.trains)