Subject:
|
Re: Power Functions presentation
|
Newsgroups:
|
lugnet.technic
|
Date:
|
Tue, 9 Oct 2007 11:44:23 GMT
|
Viewed:
|
8508 times
|
| |
| |
> Thanks for updating your site. It is a great resource!
> I was wondering if you have any data on the IR receivers that come with the
> power functions in terms of current handling capacity (for example, is it OK to
> wire multiple XL motors to one output?).
Hello David,
It is OK (driver IC is thermally protected), but not recommanded. Only one XL
motor can absorb more current than the dirver inside IR receiver is able to
provide (800mA)... But why not if they are lightly loaded.
There are some official answers about these questions in PF faq:
http://www.lego.com/eng/service/faqs.asp?section=ConsumerService-FAQ-Products&catid=2BCCCC7B-FD01-4AAE-AD0F-35244A7898DC&faqid=38338#38338
Philo
|
|