I might be wrong here, but I think you've almost
got it figured out. I think the flickering is there becuase
it gets turned off during regular comms or the IR range
finding so that it doesn't get too confused!

In otherwords, you can turn on the laser, but it gets turned
off during range finding or other comms.

I wonder what happens if you "cloak" the Spybot by sending it the
cloak message....

Cheers, Ralph

-----Original Message-----
From: news-gateway@lugnet.com [mailto:news-gateway@lugnet.com]On Behalf
Of Steve Hassenplug
Sent: Thursday, August 29, 2002 2:54 PM
To: lugnet.robotics.spybotics@lugnet.com
Subject: Re: Spybotics To RCX Comm


well, no.  It's easy to get it to turn on, but it doesn't stay on.  It flickers.  I'm sure it can be controlled (because
it's used to send data) but just using OnFwd(OUT_C); causes it to flicker.

Steve

----- Original Message -----
From: "Dean Husby" <nntp@akasa.bc.ca>
Date: Thu, 29 Aug 2002 18:45:52 GMT
To: lugnet.robotics.spybotics@lugnet.com
Subject: Re: Spybotics To RCX Comm


"Steve Hassenplug" <hassenplug@mail.com> wrote in message
news:20020829180609.1089.qmail@verizonmail.com...
Yes, I use NQC and BricxCC to program it.  It's very simple, and I just
set motor port C to forward

So you got it to stay on for the Spybot?

If so, I'm glad I could be of help.

Dean

--
_______________________________________________
Talk More, Pay Less with Net2Phone Direct(R), up to 1500 minutes free!
http://www.net2phone.com/cgi-bin/link.cgi?143




Message is in Reply To:
  Re: Spybotics To RCX Comm
 
well, no. It's easy to get it to turn on, but it doesn't stay on. It flickers. I'm sure it can be controlled (because it's used to send data) but just using OnFwd(OUT_C); causes it to flicker. Steve ----- Original Message ----- From: "Dean Husby" (...) (22 years ago, 29-Aug-02, to lugnet.robotics.spybotics)