(...) The code generated by NQC appears to be correct. I've had reports over the years from lots of people who have had great success with using the world relation table information in the Spybot so I doubt that the firmware is buggy in this respect (...) (19 years ago, 8-Jun-05, to lugnet.robotics.spybotics)
(...) Nope. NQC is definitely generating bad code. My apologies. I will fix it right away. John Hansen (19 years ago, 9-Jun-05, to lugnet.robotics.spybotics)
(...) The Spybot LASM Opcode documentation for this opcode is just plain wrong. It says that the command structure is 6 bytes. The first byte is the opcode 0xd5. The second byte is the variable number. The third byte is the "find source" (relation (...) (19 years ago, 9-Jun-05, to lugnet.robotics.spybotics)