To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.pbforthOpen lugnet.robotics.rcx.pbforth in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / pbFORTH / 112
    Do the high resolution timers work? —Jonathan Knudsen
   Hi Ralph, Are timer_SET and timer_GET working? I can't seem to get any non-zero values from them: RCX_INIT ok 0 FFFF timer_SET ok 0 timer_GET . 0 ok Am I missing something? Thanks, Jonathan (25 years ago, 27-Jul-99, to lugnet.robotics.rcx.pbforth)
   
        RE: Do the high resolution timers work? —Ralph Hempel
   (...) Yep, you've got the parameters backwards. Try FFFF 0 timer_set. Also, I'm not sure about numbers above 0x8000... I'm working on a TclTk interface for uploading firmware images to the RCX and for pbFORTH scripts. I ALMOST have the comment (...) (25 years ago, 27-Jul-99, to lugnet.robotics.rcx.pbforth)
 

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR