    Re: temperature sensor problem —Dave Baum
   Ben, Internally, the RCX only works with integers, but .1 degree resolution was desired for temperature sensors, so the sensor values are actually measured in .1 degree increments. A reading of 70 degrees F is stored as 700, not 70. If you change (...) (24 years ago, 3-Jul-00, to lugnet.robotics.rcx.nqc)
   
        Re: temperature sensor problem —Ben Erwin
   ahhh... there it is. page 312. thanks. :) i think i saw that 3-digit stuff before and i forgot about it. and thanks for the idea about the until. -ben (...) of (...) (24 years ago, 3-Jul-00, to lugnet.robotics.rcx.nqc)
   
        Re: temperature sensor problem —Dave Baum
   (...) No problem. Most of the other environments hide this sort of thing programmer, but this relies on the fact that the programming environment knows how each sensor is going to be used. I didn't think this fit with the C philosophy*, so (...) (24 years ago, 4-Jul-00, to lugnet.robotics.rcx.nqc)
 