To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcx.nqcOpen lugnet.robotics.rcx.nqc in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / NQC / 1646
1645  |  1647
Subject: 
OutputStatus
Newsgroups: 
lugnet.robotics.rcx.nqc
Date: 
Sat, 13 Mar 2004 22:46:00 GMT
Viewed: 
4723 times
  
Hi!

I think many of you wonder what results you get with the command
OutputStatus(OUT_x).

I have tested it and here are the results:

SetPower | Float Fwd | Float Rev | Off Fwd | Off Rev | OnFwd | OnRev
------------------------------------------------------
  0 | 0 | 8 | 72 | 64 | 136 | 128
  1 | 1 | 9 | 73 | 65 | 137 | 129
  2 | 2 | 10 | 74 | 66 | 138 | 130
  3 | 3 | 11 | 75 | 67 | 139 | 131
  4 | 4 | 12 | 76 | 68 | 140 | 132
  5 | 5 | 13 | 77 | 69 | 141 | 133
  6 | 6 | 14 | 78 | 70 | 142 | 134
  7 | 7 | 15 | 79 | 71 | 143 | 135

Unfortunately I cant post a good chart here, but I hope you can read out the
information.

Hope, I could help you.



1 Message in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR