 Robotics / RCX / NQC / *837 (-10)
  Timing of RCX statements
 
I was trying to simulate a serial link by using an output of the RCX. I didn't work and when I analyzed the timing, I found out that the RCX's execution of statements is far too slow for the protocol I wanted to simulate. So I made some measurements (...) (24 years ago, 23-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Monitor() and Event()
 
Can someone teach me more on Monitor() and Event()? Does the Monitor() check the event status repeatly or we have to make a repeat task to activate the monitoring job? If it is not checking the event status repeatly, why we cannot just read the (...) (24 years ago, 23-Oct-00, to lugnet.robotics.rcx.nqc)
 
  NQC 2.2 r2 released
 
A few minor bug fixes from r1 (URL) reply to: dbaum at enteract dot com (24 years ago, 22-Oct-00, to lugnet.robotics.rcx.nqc)  
 
  Re: RCX Code tutorial or better program all together?
 
(...) There sure is.... NQC, a program of the gods. (URL) the news group lugnet.robotics.rcx.nqc is where you discuss NQC. -- Coin-Op's For Sale!: (URL) Lego Workshop: (URL) Lego Club: (URL) (24 years ago, 19-Oct-00, to lugnet.robotics, lugnet.robotics.rcx.nqc)
 
  Re: Connecting 2 RCXs
 
(...) Hook up the output of RCX.A to the Input of RCX.B. Set the RCX.B's input to Touch. Now toggle the RCX.A's output from OFF and float. This will turn the ground 'short' on and off and work Exactly like a switch. No power runs though the Input (...) (24 years ago, 19-Oct-00, to lugnet.robotics.rcx.nqc)
 
  NQC and RCXCC
 
Using NQC together with RCXCC (by Mark Overmars) is a fine combination that fulfills my demands for writing software, debugging and testing. Unfortunately, Mark Overmars, the author of RCXCC will not do any further development for this product. (...) (24 years ago, 19-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Connecting 2 RCXs
 
The IR interface is one way to establish a "connection" via messages between 2 RCXs and it works fine if both of the RCXs will receive a message - directly or by multiple reflections within the room. However, it is a slow communication. My problem (...) (24 years ago, 19-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Re: Vision Command
 
No. There isn't any. You cannot control the camera form NQC or the RCX for that matter. You can respond to the messages that the Camera sends to the brick via Message(). I hope this syntax is right.... until(Message)>0); switch(Message()) case 1: // (...) (24 years ago, 18-Oct-00, to lugnet.robotics.rcx.nqc)
 
  Vision Command
 
Is there syntax that I am missing to address the "Vision Command" camera? Thanx! Ed (24 years ago, 18-Oct-00, to lugnet.robotics.rcx.nqc)
 
  "True" Interrupts
 
When I did some work with the new control structures, I found out that they are quite nice (monitor and acquire). However, you could do the same in the past but you needed to split your program into several tasks which are controlled of a task (...) (24 years ago, 11-Oct-00, to lugnet.robotics.rcx.nqc)