i there a table or converter from brickos light readings to light
percentage ( and vice versa )

Thomas



Message has 2 Replies:
  Re: table brickos light to percent
 
(...) Hi Thomas, Here's the formula used in the dsensor.h include file: #define ds_scale(x) ((unsigned int)(x)>>6) //!< mask off bottom 6 bits #define LIGHT(a) (147 - ds_scale(a)/7) //!< map light sensor to 0..LIGHT_MAX This maps the raw sensor (...) (20 years ago, 27-May-04, to lugnet.robotics.rcx.legos)
  Re: table brickos light to percent
 
In my opinion, the best way to approach this is the following: When the program starts, begin a Calibration, by first activating the light sensor, then reading the value. You can either wait a specific amount of time or have the user press a button (...) (20 years ago, 27-May-04, to lugnet.robotics.rcx.legos)