    Use built-in Ir instead of IR-Tower? —Roman Schmidmeir
   Hi! i have a sub-notebook without any com-ports so i can't use my IR-Tower. But the built in IR is reachable over com5 (btw: i'm working with cygwin). so i changed dll to com5 (export...) but now i get the error(when dll'ing): Error 21: sending (...) (22 years ago, 29-Sep-02, to lugnet.robotics.rcx.legos)
   
        Re: Use built-in Ir instead of IR-Tower? —Jochen Hoenicke
   (...) The IR protocol is slightly different. While IRDA only sends short pulses the Lego Tower sends a signal for the whole time slot. It is very unlikely that one can get them work together. Jochen (22 years ago, 30-Sep-02, to lugnet.robotics.rcx.legos)
 