    Re: rotation sensor problem (different one this time) —Paolo Masetti
   (...) All sensors stops responding? I think that you have lost, for some reasons, the ADC sampling IRQ... If you loose this one you have lost the kick to continue sampling... Some part of code inside legOS disable IRQs... I'm not enough expert in H8 (...) (24 years ago, 27-Jul-00, to lugnet.robotics.rcx.legos)
   
        Re: rotation sensor problem (different one this time) —Luis Villa
   (...) Nope, just rotation. Well, I can't be sure, since there are no other sensors, but since it is not permanent (i.e., I can still force it to register, just at the wrong times) I doubt I have lost the IRQ. (...) No signals at all. I'll try it (...) (24 years ago, 27-Jul-00, to lugnet.robotics.rcx.legos)
 