To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / 780
779  |  781
Subject: 
Re: Use PC's IR port instead of IR tower?
Newsgroups: 
lugnet.robotics.rcx
Date: 
Tue, 10 Oct 2000 12:17:27 GMT
Viewed: 
3792 times
  
In theory it's possible, provided that:

[1] The optical frequency matches adequately (anyone know?)
[2] 38400 Hz is close enough to the RCX/Scout modulation frequency to get
    past any bandpass filtering..
[3] The PC software can accurately turn IR on/off at 2400baud in software
    (I see no problem with this under interrupt control in DOS).

If I get my oscilloscope back from a relative (!), and I can prise the Scout
off the kids occaisionally I'll give it a go. It won't be a Win32 solution :)

Phil.

Reimer Mellin wrote:
> 
> The basic difference between PCs/PalmPilots/WinCE IR ports and the RCX is a
> different physical transmission/modulation protocol. In the PC etc case the
> commonly used format is described by the IrDa standard (www.irda.org) where
> seperate IR pulses are used to transmit Bits. The RCX uses a  format
> 'loaned' from Remote controls where a IR carrier frequency is used to
> transmit bits in a similar fashion to radio transmission (i.e. a missing
> period in the carrier denotes a Bit).
> 
> However, I have seen applications where a PC was turned into a remote
> control for TVs etc by programming the IR hardware directly. Obviously thats
> HW dependant. Check the following links for more information:
> http://www.ee.washington.edu/eeca/circuits/PCIR/Welcome.html
> http://www.chambord-tech.com/
> http://www.dodgies.demon.co.uk/FAQ/IrDa.html
> 
> Cheers
>     Reimer
> 
> Brad Aisa <baisa@NOSPAMbrad-aisa.com> wrote in message
> news:38277AEC.2FA599A0@NOSPAMbrad-aisa.com...
> > Hello,
> > 
> > Is it possible to use a PC's IR port, instead of the IR tower, to
> > communicate with an RCX?
> > 
> > (I have a Dell Inspiron 3500).
> > 
> > --
> > Brad Aisa
> > baisa@NOSPAMbrad-aisa.com  -- PGP public keys available at:
> > http://keys.pgp.com:11371/pks/lookup2?op=index&search=Brad+Aisa
> > 
> > "Laissez faire."



Message is in Reply To:
  Re: Use PC's IR port instead of IR tower?
 
The basic difference between PCs/PalmPilots/WinCE IR ports and the RCX is a different physical transmission/modulation protocol. In the PC etc case the commonly used format is described by the IrDa standard (www.irda.org) where seperate IR pulses (...) (27 years ago, 12-Nov-99, to lugnet.robotics.rcx)

3 Messages in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR