      Well, it's hard to say what the problem might be. Since you've got the green 
LED going, you've probably got the cable wired correctly. And yes, it's 2400 
baud, 1 start, 1 stop, 8 data, odd parity. Perhaps the packet isn't correct. 
Here's a sample packet to send the remote control style command for "motor A 
fwd". With the remote control commands you don't have to worry about return 
info from the RCX. 
(in hex:) 
55 ff 00 d2 2d 00 ff 08 f7 da 25 
 
good luck, 
Mike Kory 
 |  
       |  
           
   
        Message is in Reply To:
             |    | Serial Comm with RCX
  |  
  |  I am trying to connect my HP49 Calculator with the Mindstorms IR Tower, I thought I had got the protocols right, the Green LED lights when I send the packet but nothing else, no reply from the RCX. Am I missing something?. Protocol 2400 baud odd (...)   (26 years ago, 16-Nov-99, to lugnet.robotics.rcx)   
   |         