    Re: To all sensor developers, why use voltage drive ? —Michael Gasperi
    Stef Mientki <s.mientki@ids.kun.nl> wrote in message news:3AA01C30.6FFBA7....kun.nl... (...) sensor-cirquit, while the RCX sense input is in fact a current sensing input ? What the RCX measures is voltage. It has a 10k pull up to 5V, but it (...) (24 years ago, 3-Mar-01, to lugnet.robotics.rcx)
   
        Re: To all sensor developers, why use voltage drive ? —Stef Mientki
   hi Michael, thanks for you reaction. (...) So here I disagree with you , you are correct if you'r saying the inside AD-converter is measuring voltage, but we're not dealing with the AD-converter alone, but with a combination of the AD-converter, the (...) (24 years ago, 3-Mar-01, to lugnet.robotics.rcx)
   
        Re: To all sensor developers, why use voltage drive ? —Michael Gasperi
    Stef Mientki <s.mientki@ids.kun.nl> wrote in message news:3AA0BF7B.46088E....kun.nl... (...) AD-converter is measuring voltage, but we're not dealing with the AD-converter alone, but with a combination of the AD-converter, the pull up resistor, the (...) (24 years ago, 3-Mar-01, to lugnet.robotics.rcx)
 