To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.rcxOpen lugnet.robotics.rcx in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / RCX / *5545 (-10)
  Re: Shuting up the RCX
 
(...) Right, that's an option but perhaps not the ideal for me since I'm working with NQC. Any other? Thanks anyway Jürgen. (23 years ago, 18-Dec-01, to lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  Re: How to get interval of time
 
(...) correct? Yep, that's how I do it & it seems to work. ROSCO (23 years ago, 18-Dec-01, to lugnet.robotics.rcx.legos)
 
  How to get interval of time
 
In NQC, I can use ClearTimer(0) and Timer(0) to get interval of time, how can I do it in legOS? I used t1 = sys_time, then t2 = sys_time, so interval = t2 - t1, is it correct? Zhengrong (23 years ago, 18-Dec-01, to lugnet.robotics.rcx.legos)
 
  Robot Controller 1.2b1
 
I've posted a new version of Robot Controller ---the ideal companion to NQC for Mac OS X users. This version fixes a couple of bugs. Download from: (URL) the way, has anyone tried it? It would be nice to get some feedback! Barney. (23 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc)
 
  Re: RCX remote control and the use of PICs
 
Hi Stef, A great project, well designed, and very well documented and presented. Thanks! I'll probably make one of these pretty soon. Nice work Michael (...) (23 years ago, 17-Dec-01, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  RCX remote control and the use of PICs
 
hi All, Inspired by some applications of the 16F84 PIC, we came up with the idea to make a IR-module, which is capable of doing all the InfraRed tasks we could imagine with the RCX. Well it hasn't come so far, but we have build a RCX IR-remote (...) (23 years ago, 17-Dec-01, to lugnet.robotics, lugnet.robotics.rcx, lugnet.robotics.rcx.nqc)
 
  Re: How to read the touch sensors on the Scout in NQC?
 
I was using my scout this past weekend as a coinbox detector to launch a mono rail. The touch sensors work exactly as Dave suggests. You can also just do the following: until(SENSOR_1); Waits until it's touched. until(!SENSOR_1); Waits until the (...) (23 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Re: Shuting up the RCX
 
(...) Change the firmware. Maybe we should make this a selling point of Lejos :-) (at the moment it beep too, I think) Jürgen (23 years ago, 17-Dec-01, to lugnet.robotics.rcx)
 
  Re: How to read the touch sensors on the Scout in NQC?
 
(...) That is what I thought, but it will determine if the touch sensor is pressed. (...) Dunno, I'll try. Then again, if !=255 works... (...) If it were not for Perl I'd never write a line of code ^_^ (23 years ago, 17-Dec-01, to lugnet.robotics.rcx.nqc, lugnet.robotics.scout)
 
  Shuting up the RCX
 
Hi all. Just a simple question, does anybody know if there is anyway to stop rcx beeping everytime i turn it on or off. It is terribly annoying at 2:00 in the morning :-) Thank Francis (23 years ago, 17-Dec-01, to lugnet.robotics.rcx)


Next Page:  5 more | 10 more | 20 more

Redisplay Messages:  All | Compact

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR