    Re: Hi-speed port communication —Juergen Stuber
   Hi Ross, (...) it should be possible to use RS-485 as a bus, i.e. connect several NXTs with one cable. You need to make the cable yourself, though, and you may need some termination on the ends. Jürgen (17 years ago, 4-Jan-08, to lugnet.robotics.nxt)
   
        Re: Hi-speed port communication —Christian Mock
   (...) Hi all, the physical connection of NXTs via RS485 is just the first half of the solution... Remeber, at 2-wire RS485 you can have one master only and up to 31 slaves. To address each slave, you need to implement a special protocol which (...) (17 years ago, 5-Jan-08, to lugnet.robotics.nxt)
   
        Re: Hi-speed port communication —John Hansen
   I posted a zip to the NXC samples page containing a pair of programs that show how to send a message from one NXT to another over a wire connected between port 4 on both NXTs. (URL) Hansen (17 years ago, 7-Jan-08, to lugnet.robotics.nxt)
 