  Re: JRM code and Reset
 
Since it seems like everything else has been checked, I have one other suggestion after looking at my pcode source. If the "start" button on the HB is pressed during power on, the autostart will be disabled. Has your hardware been hacked at all, (...) (23 years ago, 2-Jan-02, to lugnet.robotics.handyboard)
 
  Re: JRM code and Reset
 
Matt, The only mod I've made to my HB is to cut the motor power supply "+" trace and use a separate motor power supply. See my post/response to Dan for my explanation of that. After reading your START button question, I triple checked. I don't (...) (23 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  main() Reset -- THE SAGA ENDS !! ---
 
Fellow Lugnuts, Doe anyone want to purchase a 74HC244 (U5) that "kinda works" ? YES, YES, believe it or not, U5 was my problem !! The mystery is not totally solved, because even using both a logic probe and an o-scope, I cannot see any indication (...) (23 years ago, 3-Jan-02, to lugnet.robotics.handyboard)
 
  Re: main() Reset -- THE SAGA ENDS !! ---
 
Awsome!!! Now we are expecting great things from you :-) -Dan (...) (23 years ago, 3-Jan-02, to lugnet.robotics.handyboard)