To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.handyboardOpen lugnet.robotics.handyboard in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / Handy Board / 7342
7341  |  7343
Subject: 
Re: sonar
Newsgroups: 
lugnet.robotics.handyboard
Date: 
Sun, 23 Jan 2000 18:04:25 GMT
Viewed: 
989 times
  
however, when i run the program, i receive numbers
which i am not sure i understand. after i convert the
numbers returned from the sonar to approximate
distances (feet), i get sequences such as:
1.7
-2.4
5.2
.5
-6.1

i don't understand the negative numbers. or the
sequences.

would this be related to the note on the website about
the installing a 0.1 µF capacitor in the C7 position?
if so, how does one do that?
I would imagine that this is the case since Fred states on his page that it
won't work without it on most versions of the driver board.

The easiest way to do it is just desolder the two pads that align with the
c7 position on the HB.  Stick a small electrolytic in there, get the
polarity correct!  (it's marked on the board with a + I believe).  and
resolder the cap in place.  It's quite easy, but let me know if you have any
problems.

I can't say for certain that this is why this is happening since I've never
hooked it up without the cap, but I'd think it's likely.

Good luck,

-Jim Munro
<jimmn@xnet.com>



1 Message in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR