Will & Keith,
The following information is in a file called readme.ic that should be
in your IC directory.
By Default IC will use COM1. If you need IC to use a different serial
port, you can run it with argument like so:
ic -port com2
or you can run ic with the -config option to reconfigure IC.
Good luck
Jim
> lectro@acadiacom.net wrote:
> >
> > I had a similar problem and had to try a different serial port. I have a
> > serial mouse and the board will only work properly in com 1. If I try com
> > 2, I get similar problems to yours
> >
> > keith
>
> DOING! Yeah, now that you mention it, I had the same problem when I got my
HB. Took me about a week before I got around to trying COM1. That fixed
it, so I left it that way and forgot about it long ago. At the time, no one
on the list had any helpful suggestions for me, either.
>
> Anyone else out there had problems using COM2 with a serial mouse on COM1?
>
> -- Will
> , ,
> __@_/ \_@__ |/
> | /__, o @_/
> )\ ) ( \ (\/\\,
> ~~~~~~~~~ ' ` ~~~~~~~~~~~ ` ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
> Wendy Parson, Every improvement in communication
> Will Bain, makes the bore more terrible.
> & Tatoosh --Frank Moore Colby
>
|
|