To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.handyboardOpen lugnet.robotics.handyboard in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / Handy Board / 4992
4991  |  4993
Subject: 
Re: a/d range
Newsgroups: 
lugnet.robotics.handyboard
Date: 
Sun, 20 Dec 1998 01:20:16 GMT
Original-From: 
Cesar Mello <cmello@cpovo!IHateSpam!.net>
Viewed: 
1065 times
  
Hi friends!

Thank you for the replies about this topic. Now I could get a Reference
Manual too...

The a/d range is determined by the references given to the VrefH and VrefL
pins. But be careful about this:

"There should be at least 2.5V between VREFL and VREFH for full A/D
accuracy. Lower values will result in more inaccuracy, but the converter
will continue to operate. The A/D system is tested at 4.5 and 5.5V across
the reference supply pins."

See you,
Cesar



1 Message in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR