Subject: 
Other batteries...
Newsgroups: 
lugnet.robotics.handyboard
Date: 
Wed, 18 Nov 1998 20:35:56 GMT
Original-From: 
wengd@optionshealthcare+StopSpammers+.com
Viewed: 
1666 times
  
Is it ok to use batteries of the sealed lead-acid type (from a UPS).  I have

V 7.5 Ah and I was wondering if the battery charge circuts would
work correctly if I simply replaced the NiCd pack with the lead-acid
battery.  Are there any considerations other than charging.
-Drew



Message has 1 Reply:
  Re: Other batteries...
 
A gell cell battery is charged via a maximum allowed charging voltage. If the charger doesn't limit the charging voltage to less than 14 volts it will shorten the life of a 12v gell cell considerably. A Ni-Cad uses a constant charging current, but (...) (26 years ago, 19-Nov-98, to lugnet.robotics.handyboard)