Subject:
|
running 2 IR
|
Newsgroups:
|
lugnet.robotics.handyboard
|
Date:
|
Sun, 6 Apr 1997 15:24:58 GMT
|
Original-From:
|
victor w clark <kvclark@junoIHATESPAM.com>
|
Viewed:
|
1372 times
|
| |
| |
I want to be able to run 2 or 3 IR xmitters from the single output on the
HB with no additional hardware.
Is there any problem with hooking two or 3 IR transmitters to the ground
of the IR output and running the +5v from digital outputs. Then switch
thru each one using the digital output. Only having one active at any
given moment.
|
|
Message has 1 Reply: | | Re: running 2 IR
|
| You mean IR "emitters"? (IR LED) If i understand you correctly, you wish to source current with the digital outputs. The digouts are from the HC11. There can't source enough current to light IR LED's. ---...--- ericson mar Master of Engineering (...) (27 years ago, 6-Apr-97, to lugnet.robotics.handyboard)
|