To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.robotics.handyboardOpen lugnet.robotics.handyboard in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / Handy Board / *6034 (-5)
  Re: help about part C3
 
use Digikey P6305-ND or P5417-ND. both are 470 uF electrolytics, axial leads (that is, leads sticking out opposite ends) and are 16 mm long and 8 mm in diameter. in other words, they're the right value and they'll fit. F. (...) (25 years ago, 13-Apr-99, to lugnet.robotics.handyboard)
 
  help about part C3
 
Can anyone tell me of a good place to get part C3 for the handy board?...DigiKey no longer has it or a replacement. -Jon Schuck (25 years ago, 13-Apr-99, to lugnet.robotics.handyboard)
 
  Has anyone an icb-routine for 9600b serial connection ?
 
Hi, i used the serialio.c routines to establish a data connection between the Handyboard and a Linux PC and encountered the same problems already mentioned in the mailing list: 1) Only char by char transmission with sleeps between transmissions (...) (25 years ago, 13-Apr-99, to lugnet.robotics.handyboard)
 
  Re: Servo DEinitialization.
 
Sorry. I'll reread the documentation. I was going by memory. Fred G. Martin Fred G. Martin (...) Ross Tonkens (25 years ago, 13-Apr-99, to lugnet.robotics.handyboard)
 
  Re: Servo DEinitialization.
 
(...) as it says in the docs: init_expbd_servos(int action) If action is zero, servo control signals are disabled. If action is non-zero, servo control signals are enabled. Control signals are disabled by default every time the Handy Board is reset. (...) (25 years ago, 13-Apr-99, to lugnet.robotics.handyboard)