Take a look at my page to find out how the CyberMaster protocol works
(it is not the very same as the RCX), and to find som sample programs in C
and Perl
that works.


http://www.viktoria.informatik.gu.se/~peter/lego/

//Peter

At +0000 1/25/99 21:24, you wrote:
Hello there,
I am experimenting with the Cybermaster, but is not able to
get the communication line up between the PC and rcx radio tower.
(I use Visual Prolog for programming).

I use 2400bps 8 bit no parity 1 stopbit
I am sending a byte sequence like the following:
0x55 0xFF 0x00 0x10 0xEF 0x10
where the three first bytes are the header,
0x10 is data and 0xEF is complimentary to 0x10
and the last 0x10 is checksum (sum of all data mod 256)

The light on the rcx radio tower is blinking when I send the data
but the light on the rcx is not blinking as it should when receiving data.

I get nothing back to th PC.

Do I need some advice or should I take up collecting stamps?

Thanks
Sten Kvamme
--
Did you check the web site first?: http://www.crynwr.com/lego-robotics

-------------------------------------------------------------------------
Peter Ljungstrand; PLAY Research Group, Viktoria Institute

http://www.viktoria.informatics.gu.se
Email: peter@informatics.gu.se
Phone: +46-(0)31-7735543        Mobile: +46-(0)708-302251
Fax: +46-(0)31-7735530        ICQ: 6820636
Visitors: Viktoriagatan 13, 7th floor
Snail-mail: Box 620, 40530 Göteborg, Sweden

--
Did you check the web site first?: http://www.crynwr.com/lego-robotics



Message is in Reply To:
  Communicating with Cybermaster not easy
 
Hello there, I am experimenting with the Cybermaster, but is not able to get the communication line up between the PC and rcx radio tower. (I use Visual Prolog for programming). I use 2400bps 8 bit no parity 1 stopbit I am sending a byte sequence (...) (26 years ago, 25-Jan-99, to lugnet.robotics)

2 Messages in This Thread:

Entire Thread on One Page:
Nested:  All | Brief | Compact | Dots
Linear:  All | Brief | Compact
    

Custom Search

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR