To LUGNET HomepageTo LUGNET News HomepageTo LUGNET Guide Homepage
 Help on Searching
 
Post new message to lugnet.roboticsOpen lugnet.robotics in your NNTP NewsreaderTo LUGNET News Traffic PageSign In (Members)
 Robotics / 22844
  Re: RCX 2.0 Power Supply
 
(...) Thanks for pointing that out, Philo. I think I'll stick to the non-hopped up version! :-) (...) Hopefully you didn't find this out the hard way... Mark (20 years ago, 15-Sep-04, to lugnet.robotics, lugnet.trains, FTX)
 
  Re: RCX 2.0 Power Supply
 
(...) A friend did the mistake for me... but I had to repair a few of his RCXs! The connector he used to plug an external supply was prone to be shorted (on RCX side) when he unplugged it. It was only several fuses later that we understood the (...) (20 years ago, 16-Sep-04, to lugnet.robotics, lugnet.trains, FTX)

©2005 LUGNET. All rights reserved. - hosted by steinbruch.info GbR