  Re: RCX 2.0 Power Supply
 
(...) Indeed, the input capacitor of the RCX is rated 10V, so I would not do that for a too long time. This 1000µF capacitor, used to keep memory during battery exchange, is directly connected to RCX board supply input. By the way, this capacitor is (...) (20 years ago, 15-Sep-04, to lugnet.robotics, lugnet.trains, FTX)
 
  Re: RCX 2.0 Power Supply
 
(...) Thanks for pointing that out, Philo. I think I'll stick to the non-hopped up version! :-) (...) Hopefully you didn't find this out the hard way... Mark (20 years ago, 15-Sep-04, to lugnet.robotics, lugnet.trains, FTX)
 
  Re: RCX 2.0 Power Supply
 
(...) A friend did the mistake for me... but I had to repair a few of his RCXs! The connector he used to plug an external supply was prone to be shorted (on RCX side) when he unplugged it. It was only several fuses later that we understood the (...) (20 years ago, 16-Sep-04, to lugnet.robotics, lugnet.trains, FTX)