 | | Re: robolab 2.9
|
| (...) Just a quick correction. You do need to own a previous version of ROBOLAB. Version 2.9 is just an upgrade. -j. (20 years ago, 24-May-06, to lugnet.robotics.rcx.robolab)
| | |  | | Re: Ultrasonic sensor interactions
|
| Hello John, (...) I have played with this command, it seems that only the low nibble of paramater is useful. The interval range goes from 12.5ms for 0 to 3s for 0xf. Interval seems to be roughly proportional to the square of the parameter. I have (...) (20 years ago, 24-May-06, to lugnet.robotics)
| | |  | | Re: robolab 2.9
|
| (...) No, you do not need an earlier version. (...) No, it will not work with the 9753 Technic Control Center. But it works with the 9751 Control Lab Interface if that's what you are meaning. CSSoh (20 years ago, 24-May-06, to lugnet.robotics.rcx.robolab)
| | |  | | Re: Ultrasonic sensor interactions
|
| (...) Excellent! Thanks for the update, and it's great to know this is availible within the HW. I wish NXT-G had access, but... well, either it eventually will, or LEGO has specificly included goodies in the FW just for 3rd party environments. (...) (20 years ago, 22-May-06, to lugnet.robotics)
| | |  | | Re: Ultrasonic sensor interactions
|
| (...) I can confirm that the 0x2, 0x41, 0x0 "off" command does, indeed, turn off the clicking sound that you can hear coming from the US sensor. I can also confirm that the 0x2, 0x40, 0xNN "set measurement interval" command does set the measurement (...) (20 years ago, 22-May-06, to lugnet.robotics)
| |