  English version of VC software - where, from?
 
Hello. I am new to LEGO Mindstorms world. I live in Poland where LEGO is not selling its Vision Command extension to Mindstorms. I have it bought in Germany. Unfortunately the software included in a.m. set was localized, and is available only in (...) (26 years ago, 31-Dec-00, to lugnet.robotics.vc)
 
  Motor Drivers
 
Hi, Currently I'm using an L298 to drive a couple of DC motors. Unfortunately the only way I can intorduce any sort of speed control is to PWM the enable line since PWM'ing the inputs for speed control does not work. Does anyone else know of any (...) (26 years ago, 31-Dec-00, to lugnet.robotics)
 
  Re: Message transmission speeds.
 
In the RCX and the tower, the IR receiver is located close to the transmitter. When the transmitter is running, the adjacent receiver's Automatic Gain Control cirucit (AGC) becomes saturated, and sets the receiver sensitivity to it's lowest possible (...) (26 years ago, 30-Dec-00, to lugnet.robotics)
 